???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: http://tede.metodista.br/jspui/handle/tede/1288
Full metadata record
DC FieldValueLanguage
dc.creatorLages, Luís Henrique Rodriguespt_BR
dc.contributor.advisor1Angelieri, Fernandapt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0452592229034595por
dc.contributor.referee1Torres, Fernando Césarpt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/0010104738516547por
dc.date.accessioned2016-08-03T16:31:17Z-
dc.date.available2011-06-27pt_BR
dc.date.issued2011-03-29pt_BR
dc.identifier.citationLAGES, Luís Henrique Rodrigues. A UTILIZAÇÃO DO LASER DE BAIXA INTENSIDADE NA MOVIMENTAÇÃO DENTÁRIA E NA SENSIBILIDADE DOLOROSA APÓS APLICAÇÃO DE FORÇA ORTODÔNTICA. 2011. 107 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2011.por
dc.identifier.urihttp://tede.metodista.br/jspui/handle/tede/1288-
dc.description.resumoO presente estudo objetivou avaliar a eficácia do Laser de Baixa Intensidade (LBI) na aceleração da movimentação dentária e na diminuição da dor frente à aplicação de força ortodôntica. A amostra foi composta por 19 pacientes, sendo doze do sexo feminino e sete do sexo masculino, com idade inicial média de 14,69 anos, todos com indicação para extrações de primeiros pré-molares. Destes, 66 caninos foram submetidos à retração inicial, sendo que 33 receberam aplicação de laser e 33 foram considerados controle. Utilizou-se o Laser de Baixa Intensidade de arseneto de gálio e alumínio, com comprimento de onda de 780nm, na dosimetria de 40mW;10J/cm2;10s/ponto, aplicado apenas uma vez ao mês em dez pontos, sendo cinco por vestibular e cinco por lingual/palatino. Modelos de gesso foram confeccionados durante todos os meses de retração dos caninos, que teve duração de quatro meses, sendo, posteriormente, digitalizados para se mensurar a quantidade de movimentação de um lado em relação ao outro, utilizando-se como referência as papilas incisivas. Para a avaliação da dor experimentada pelos pacientes, os mesmos foram orientados a preencher uma escala analógica visual (VAS) que variava de 0 a 10 , em que zero significava nenhuma dor e dez significava dor insuportável, nos intervalos de 12, 24, 48 e 72 horas após a aplicação da força ortodôntica. Foi mensurado o apinhamento de todas as hemiarcadas dos pacientes na fase inicial, medindo-se a distância entre os pontos de contato de cada dente. Para a verificação do padrão de normalidade, empregou-se o teste de Kolmogorov-Smirnov, sendo que para comparar o lado irradiado com o lado não irradiado foi utilizado o teste t pareado, exceto para a variável razão caninos/molares , analisada pelo teste não paramétrico de Wilcoxon (p<0,05). Os resultados mostraram que em relação ao apinhamento dentário, os lados irradiado e não irradiado apresentaram-se compatíveis. Além disso, não houve diferença estatisticamente significante entre a quantidade de retração dos caninos irradiados comparados aos não irradiados, o mesmo acontecendo com a sensibilidade dolorosa experimentada pelos pacientes. Concluiu-se assim que o LBI na dosimetria e forma como foi utilizado não foi eficiente na aceleração da movimentação dentária nem na redução da dor experimentada pelos pacientes frente às forças ortodônticas.por
dc.description.abstractThe purpose of this study was to evaluate the effectiveness of low level laser therapy (LLLT) on tooth movement acceleration and pain reduction during the application of orthodontic force. The sample consisted of 19 patients, twelve females and seven males, with initial mean age of 14.69 years, all with treatment planning envolving extraction of first premolars. From these, 66 canines underwent to initial retraction, therefore, 33 received laser application during this treatment phase and 33 were selected as control. It was used low-intensity laser gallium-aluminum- arsenide, with wavelength of 780nm (40mW; 10J/cm2; 10s/point applied only once a month on ten points, five at buccal side and five at palatal side). Casts were made during all phases of retraction of the canines, which had a mean duration of four months and then, this casts were scanned to measure the amount of movement of irradiated side in comparison with the control side, using as reference the incisive papilla. To avaliate the pain experienced by patients, they were asked to complete a visual analogue scale (VAS) from "0" to "10", where zero means no pain and ten means insupportable pain, in intervals of 12, 24, 48 and 72 hours after application of orthodontic force. Crowding was measured for all hemiarc of patients at onset of treatment, by the sum of the distance between the contact points of teeth. For verification of the normality, it was used the Kolmogorov-Smirnov test. To compare irradiated with control sides, it was used paired t test, except for the variable "canines / molars rate," that was compared by nonparametric Wilcoxon test (p <0.05). The results showed that crowding in irradiated and control sides were compatible. Furthermore, no statistically significant difference was observed between the amount of retraction of the irradiated canines in comparison to non-irradiated, such as the pain experienced by patients. It was concluded that the LBI in dosimetry and manner that was used in this present study was not efficient in accelerating tooth movement or reducing pain experienced by patients in response to orthodontic forces.eng
dc.description.provenanceMade available in DSpace on 2016-08-03T16:31:17Z (GMT). No. of bitstreams: 1 Pagina de 1-50 Luis Henrique Rodrigues Lages.pdf: 426503 bytes, checksum: 87201f29fd58de3542487e72c8dafdf0 (MD5) Previous issue date: 2011-03-29eng
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://tede.metodista.br/jspui/retrieve/2892/Pagina%20de%201-50%20Luis%20Henrique%20Rodrigues%20Lages.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Metodista de São Paulopor
dc.publisher.departmentOrtodontiapor
dc.publisher.countryBRpor
dc.publisher.initialsUMESPpor
dc.publisher.programPÓS GRADUAÇÃO EM ORTODONTIApor
dc.rightsAcesso Abertopor
dc.subjectTerapia a Laser de Baixa Intensidadepor
dc.subjectMovimentação Dentáriapor
dc.subjectOrtodontia Corretivapor
dc.subjectLaser Therapy, Low-Leveleng
dc.subjectTooth Movementeng
dc.subjectOrthodontics, Correctiveeng
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDEpor
dc.titleA UTILIZAÇÃO DO LASER DE BAIXA INTENSIDADE NA MOVIMENTAÇÃO DENTÁRIA E NA SENSIBILIDADE DOLOROSA APÓS APLICAÇÃO DE FORÇA ORTODÔNTICApor
dc.typeDissertaçãopor
Appears in Collections:Programa de Pos Graduação em Ortodontia

Files in This Item:
File Description SizeFormat 
Pagina de 1-50 Luis Henrique Rodrigues Lages.pdf416.51 kBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.