???item.export.label??? ???item.export.type.endnote??? ???item.export.type.bibtex???

Please use this identifier to cite or link to this item: http://tede.metodista.br/jspui/handle/tede/1214
Full metadata record
DC FieldValueLanguage
dc.creatorNicodemos, Valéria Rezendept_BR
dc.contributor.advisor1Miranda, André Luis Ribeiro dept_BR
dc.contributor.referee1Angelieri, Fernandapt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/0452592229034595por
dc.contributor.referee2Ribeiro, Daniel Arakipt_BR
dc.date.accessioned2016-08-03T16:31:02Z-
dc.date.available2013-04-04pt_BR
dc.date.issued2012-12-06pt_BR
dc.identifier.citationNICODEMOS, Valéria Rezende. Comparison between single and fractioned low-level laser application in tooth orthodontic movement of rats. 2012. 101 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2012.por
dc.identifier.urihttp://tede.metodista.br/jspui/handle/tede/1214-
dc.description.resumoO laser de baixa intensidade (LBI) tem demonstrado efeitos bioestimulatórios na movimentação ortodôntica, acelerando a resposta celular e, reduzindo o tempo de tratamento. Entretanto, o uso do LBI seria mais efetivo com maior potência, menor tempo (única irradiação), ou a junção da menor potência e tempo em aplicação fracionada? Este estudo visou quantificar a movimentação de molares de 64 ratos e suas alterações histológicas, submetidos a uma força ortodôntica, liberada por meio de uma mola fechada de níquel-titânio (Niti/25gf), calibrada em 20gf. Os animais foram divididos em quatro grupos (cada grupo com 16 ratos), de acordo com os seguintes protocolos de irradiação do laser GaAlAs(780nm): grupo controle , submetidos à movimentação ortodôntica mas sem aplicação do LBI ; grupo total 1 (P=60mW/DE=15J/cm²/Et=6J/t=100seg), com a movimentação ortodôntica associada à única aplicação do LBI laser (P=60mW/DE=15J/cm²/Et=6J/t=100seg) no dia zero. Grupo total 2 em que o LBI foi aplicado no dia 0, segundo o protocolo P=20mW/DE=15J/cm²/E=6J/t=300seg;,; e Grupo fracionado em que o LBI foi aplicado nos dias 0, 3 e 7, empregando-se o protocolo (P=20mW/DE=5J/cm²/E=2J/t=100seg). Os sacrifício dos ratos foi realizado em quatro momentos (dias 1,4,8 e 15), sendo que 4 ratos de cada grupo foi sacrificado em cada um dos dias. A quantidade de movimentação ortodôntica foi mensurada in loco por meio de paquímetro digital, antes da instalação das molas e, imediatamente após o sacrifício dos animais. Para o exame histológico, as maxilas foram removidas, preparadas e coradas pelo sistema H/E. Os resultados foram avaliados pela Análise de Variância, seguida do teste Tukey (p<0,05). O grupo fracionado apresentou maior movimentação dentária frente aos demais nos dias 4 e 8, sendo que os grupos total 1 e 2 demonstraram maior movimentação dentária que o controle somente no dia 8. Não houve diferença estatisticamente significante entre os grupos total 1 e 2 em todo o período avaliado. Este estudo concluiu que, o laser de baixa intensidade acelerou a movimentação dentária, salientando-se o efeito da aplicação fracionada em relação às aplicações únicas.por
dc.description.abstractLow-level laser (LLL) has proved its biostimulators effects in orthodontic movement, increasing the cell response and, reducing the treatment time. However, would the use of LLL be more effective with more power in a short time (single irradiation), or both low power and time in fractioned applications? The aim of this study was to compare the movement of 64 rats molars, and their histological changes under orthodontic force, released from a NiTi closed coil (20gf). The animals were divided into 4 groups (each group with 16 rats), according to the following protocols of laser GaAlAs(780nm): control group, under orthodontic movement, with no laser irradiation; Total 1 Group, orthodontic movement associated to a single laser application (P=60mW/DE=15J/cm2/Et=6J/t=100sec), on day zero; Total 2 Group, with laser irradiation on day zero, under the protocol (P=20mW/DE=15J/cm2/E=6J/t=300sec); and fractioned group, with LLL irradiation on days 0,3 and 7, using the protocol (P=20mW/DE=5J/cm2/E=2J/t=100sec). The animals were sacrificed in 4 moments (days 1,4,8 and 15), with four rats per group, sacrificed per day. The amount of orthodontic movement was measured in loco , with a digital caliper, before the coils were activated and, immediately after the animals sacrifice. For the histological exam, the upper jaws were removed, prepared and coloured by the H/E system. The Analysis of Variance and Tukey test were performed (p<0,05). The fractioned group revealed the greatest tooth movement, compared to the other groups (on days 4 and 8). The total 1 and 2 groups presented a greater orthodontic movement compared to control group, only on day 8, without significant statistically difference between them. This study has shown that the low-level laser accelerated the orthodontic movement, emphasizing the fractioned irradiation over the single ones.eng
dc.description.provenanceMade available in DSpace on 2016-08-03T16:31:02Z (GMT). No. of bitstreams: 1 Valeria Nicodemos.pdf: 2306539 bytes, checksum: 000f3427eef075921fa69c8b5718123c (MD5) Previous issue date: 2012-12-06eng
dc.formatapplication/pdfpor
dc.thumbnail.urlhttp://tede.metodista.br/jspui/retrieve/2637/Valeria%20Nicodemos.pdf.jpg*
dc.languageporpor
dc.publisherUniversidade Metodista de São Paulopor
dc.publisher.departmentOrtodontiapor
dc.publisher.countryBRpor
dc.publisher.initialsUMESPpor
dc.publisher.programPÓS GRADUAÇÃO EM ORTODONTIApor
dc.rightsAcesso Abertopor
dc.subjectLaserpor
dc.subjectTerapia a Laser de Baixa Intensidadepor
dc.subjectMovimentação dentáriapor
dc.subjectHistologia Comparadapor
dc.subjectRatospor
dc.subjectLasereng
dc.subjectLow-level laser therapyeng
dc.subjectTooth Movementeng
dc.subjectHistologic Comparisoneng
dc.subjectRatseng
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIApor
dc.titleCOMPARAÇÃO ENTRE A APLICAÇÃO ÚNICA E FRACIONADA DO LASER DE BAIXA INTENSIDADE NA MOVIMENTAÇÃO DENTÁRIA EM RATOSpor
dc.title.alternativeComparison between single and fractioned low-level laser application in tooth orthodontic movement of ratseng
dc.typeDissertaçãopor
Appears in Collections:Programa de Pos Graduação em Ortodontia

Files in This Item:
File Description SizeFormat 
Valeria Nicodemos.pdf2.25 MBAdobe PDFThumbnail

Download/Open Preview


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.